Back to Search Start Over

ESTIMATION OF BROMATE IN FLOUR AND FLOUR PRODUCTS BY ION CHROMATOGRAPHY USING POST COLUMN DERIVATIZATION METHOD WITH TRIIODIDE.

Authors :
Guo, Jian
Wang, Fan
Qin, Yina
He, Guangyuan
Source :
Journal of Liquid Chromatography & Related Technologies. Jan2013, Vol. 36 Issue 1, p1-11. 11p.
Publication Year :
2013

Abstract

In this study, a method is established for the evaluation of bromate residues in flour and flour products. Water is used to extract bromate from the bulk product. To remove the co-extractives that hinder Ion Chromatography (IC) and deteriorate the IC column, successive steps were taken. Bromate was separated using an IonPac AS19 column with NaOH gradient elution and detected after post-column reaction to form triiodide and UV absorbance. The investigations on the samples validate the recoveries of spiked standard as 63.2–105.0%, limit of detection (LOD) 0.5 µg/L, and relative standard deviations (RSD) <9.2%. Consequently, the assay can be applied to determine bromate in flour and flour products at trace contamination levels. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10826076
Volume :
36
Issue :
1
Database :
Academic Search Index
Journal :
Journal of Liquid Chromatography & Related Technologies
Publication Type :
Academic Journal
Accession number :
84917979
Full Text :
https://doi.org/10.1080/10826076.2011.644047