Back to Search Start Over

Comparison of Different 3.OT Magnetic Resonance Sequences for Lumbosacral Plexus and Its Branches: Preliminary Study.

Authors :
Hyukjoon Lee
Joon Woo Lee
Jee Hye Lee
Heung Sik Kang
Source :
Journal of the Korean Society of Radiology. Jan2013, Vol. 68 Issue 1, p49-55. 7p.
Publication Year :
2013

Abstract

Purpose: To prospectively evaluate four magnetic resonance sequences [ProSet, fluid attenuation inversion recovery (FLAIR), balanced turbo field echo (B-TFE), T2 Drivel for the lumbosacral plexus and its branches. Materials and Methods: Ten healthy volunteers who underwent four MRI sequences on lumbosacral area were evaluated for image quality (ito 5; 1 = poor, 5 = excellent), the number of visualized bilateral spinal nerves from L2 to Si, the overlapping vessels obscuring the plexus (1 = many, 2 = some, 3 = few), and image quality defining spinal nerves (0 = nonvisualized, 1 = poor, 2 = moderate, 3 = good). Results: The ProSet (mean = 4.2, range 3-5) and B-TFE (mean = 3.7, range 3-5) showed better image quality than others. The number of visualized spinal nerves was the largest on ProSet image (mean = 9.2, range 8-10). FLAIR (mean = 2.1, range 1-3) and 12 Drive sequences (mean = 2.1, range 1-3) discriminated the nerves well from the vessels. The main branches of the lumbosacral plexus were well visualized on both ProSet (mean = 2.9, range 2-3) and FLAIR images (mean = 2.6, range 1-3). All of these were statistically significant. Conclusion: ProSet is the best sequence in the evaluation of the lumbosacral plexus and its major branches while FLAIR can be a complementary sequence for the evaluation of nerves overlapping vascular structures. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
17382637
Volume :
68
Issue :
1
Database :
Academic Search Index
Journal :
Journal of the Korean Society of Radiology
Publication Type :
Academic Journal
Accession number :
85482923
Full Text :
https://doi.org/10.3348/jksr.2013.68.1.49