Back to Search Start Over

A Doubly Fed Induction Generator Controlled in Single-Sided Grid Connection for Wind Turbines.

Authors :
Han, Yongsu
Kim, Sungmin
Ha, Jung-Ik
Lee, Wook-Jin
Source :
IEEE Transactions on Energy Conversion. Jun2013, Vol. 28 Issue 2, p413-424. 12p.
Publication Year :
2013

Abstract

This paper proposes a configuration of wind turbine using a doubly fed induction generator (DFIG) in single-sided grid connection. The stator of the machine is connected with a direct power grid, and the rotor is controlled by an inverter without any external power source. This is called a single external feeding of DFIG (SEF-DFIG). The conventional DFIG uses an additional grid power converter to regulate the rotor power; but in SEF-DFIG, the external source of a grid power is only connected to the stator windings. Due to this feature, the rotor-side inverter can be integrated on the rotor without any slip ring. In this paper, for applying the proposed scheme to the wind turbine, the performances of the generating operation are analyzed. The experimental results of a 2.4-kW DFIM system are presented to prove the feasibility of the proposed system and method. [ABSTRACT FROM PUBLISHER]

Details

Language :
English
ISSN :
08858969
Volume :
28
Issue :
2
Database :
Academic Search Index
Journal :
IEEE Transactions on Energy Conversion
Publication Type :
Academic Journal
Accession number :
87618134
Full Text :
https://doi.org/10.1109/TEC.2013.2252177