An onsite structure parameters calibration of large FOV binocular stereovision based on small-size 2D target.
- Source :
-
Optik - International Journal for Light & Electron Optics . Nov2013, Vol. 124 Issue 21, p5164-5169. 6p. - Publication Year :
- 2013
-
Abstract
- Abstract: An onsite structure-parameter calibration method for large field of view (FOV) binocular stereovision based on a small-size 2D target is proposed. Compared with the traditional large-size target, a small-size 2D target is much easier to be manufactured with high accuracy and can be used in onsite calibration. Compared with the 1D target, a 2D target can complete the calibration quickly with fewer calibration images. Additionally, operating and maintaining a small-size 2D target are considerably convenient and flexible. Calibration experiments show that only 5 placements of the calibration target can accomplish the accurate calibration of structure parameters and the average value of 10 measurements for a distance of 1071mm is 1071.057mm with a RMS less than 0.2mm. Moreover, the measurement accuracy of the stereovision calibrated with our method is a little more accurate than that of the one calibrated with traditional method. [Copyright &y& Elsevier]
Details
- Language :
- English
- ISSN :
- 00304026
- Volume :
- 124
- Issue :
- 21
- Database :
- Academic Search Index
- Journal :
- Optik - International Journal for Light & Electron Optics
- Publication Type :
- Academic Journal
- Accession number :
- 90107792
- Full Text :
- https://doi.org/10.1016/j.ijleo.2013.03.077