Removal of malathion from aqueous solution using De-Acidite FF-IP resin and determination by UPLC–MS/MS: Equilibrium, kinetics and thermodynamics studies.
- Source :
-
Talanta . Oct2013, Vol. 115, p15-23. 9p. - Publication Year :
- 2013
-
Abstract
- In the present study, De-Acidite FF-IP resin was used to remove a highly toxic and persistent organophosphorus pesticide (malathion) from the aqueous solution. Batch experiments were performed as a function of various experimental parameters such as effect of pH (2–10), contact time (10–120min), resin dose (0.05–0.5g), initial malathion concentration (0.5–2.5µgmL−1) and temperature (25–65°C). The concentration of malathion was determined using a sensitive, selective and rapid ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method. The uptake rate of malathion on De-Acidite FF-IP resin was rapid and equilibrium established within 40min. Kinetics studies showed better applicability for pseudo-second-order model. The equilibrium data was fitted to Langmuir and Freundlich isotherm models and the isotherm constants were calculated for malathion. The values of thermodynamic parameters (ΔG 0, ΔH 0 and ΔS 0) were computed from the Van't Hoff plot of ln K C vs. 1/T which showed that the adsorption of malathion was feasible, endothermic and spontaneous. The regeneration studies were carried out which demonstrated a decrease in the recovery of malathion from 95% to 68% after five consecutive cycles. Breakthrough and exhaustive capacities of malathion were found to be 1.25mgg−1 and 3.5mgg−1, respectively. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00399140
- Volume :
- 115
- Database :
- Academic Search Index
- Journal :
- Talanta
- Publication Type :
- Academic Journal
- Accession number :
- 90311747
- Full Text :
- https://doi.org/10.1016/j.talanta.2013.04.015