386mW/20K single-stage Stirling-type pulse tube cryocooler.
- Source :
-
Cryogenics . Oct2013, Vol. 57, p195-199. 5p. - Publication Year :
- 2013
-
Abstract
- Highlights: [•] A single-stage Stirling-type multi-bypass pulse tube cryocooler has been built and tested. [•] The lowest no-load temperature is 15.5K. [•] A cooling capacity of 386mW/20K can be achieved with the input power of 246W. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00112275
- Volume :
- 57
- Database :
- Academic Search Index
- Journal :
- Cryogenics
- Publication Type :
- Academic Journal
- Accession number :
- 90433665
- Full Text :
- https://doi.org/10.1016/j.cryogenics.2013.03.004