Back to Search Start Over

386mW/20K single-stage Stirling-type pulse tube cryocooler.

Authors :
Chen, Liubiao
Zhou, Qiang
Jin, Hai
Zhu, Wenxiu
Wang, Junjie
Zhou, Yuan
Source :
Cryogenics. Oct2013, Vol. 57, p195-199. 5p.
Publication Year :
2013

Abstract

Highlights: [•] A single-stage Stirling-type multi-bypass pulse tube cryocooler has been built and tested. [•] The lowest no-load temperature is 15.5K. [•] A cooling capacity of 386mW/20K can be achieved with the input power of 246W. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00112275
Volume :
57
Database :
Academic Search Index
Journal :
Cryogenics
Publication Type :
Academic Journal
Accession number :
90433665
Full Text :
https://doi.org/10.1016/j.cryogenics.2013.03.004