Back to Search Start Over

Optimum DC Bus Voltage Analysis and Calculation Method for Inverters/Motors With Variable DC Bus Voltage.

Authors :
Yu, Chen-Yen
Tamura, Jun
Lorenz, Robert D.
Source :
IEEE Transactions on Industry Applications. Nov2013, Vol. 49 Issue 6, p2619-2627. 9p.
Publication Year :
2013

Abstract

In this paper, an online method to calculate the optimum dc bus voltage for motors and inverters with variable dc bus voltages is proposed. The required dc bus voltage in the low-speed region is much lower than that for the rated-speed region. As a result, the machine drive system efficiency can be improved with lower dc bus voltage since the switching losses in the inverter are reduced. To achieve both desired machine output torque and minimized losses simultaneously, an optimum dc bus voltage is required. However, machine parameter estimation errors and spatial harmonics in the machine result in calculation errors for the required dc bus voltage. A voltage disturbance state filter (VDSF), which is formed by a Luenburger-style closed-loop stator current vector observer with voltage command feedforward, is used to mitigate the calculation errors. Voltage errors caused by the parameter deviations and machine spatial harmonics will inherently be estimated by the observer's state feedback controller. Therefore, the calculation voltage error can be corrected by the VDSF's disturbance voltage so that the optimum dc bus voltage can be obtained. [ABSTRACT FROM PUBLISHER]

Details

Language :
English
ISSN :
00939994
Volume :
49
Issue :
6
Database :
Academic Search Index
Journal :
IEEE Transactions on Industry Applications
Publication Type :
Academic Journal
Accession number :
92520589
Full Text :
https://doi.org/10.1109/TIA.2013.2265873