Back to Search
Start Over
Monitoring of concrete structures by using the 14 MeV tagged neutron beams.
- Source :
-
Radiation Measurements . Dec2013, Vol. 59, p193-200. 8p. - Publication Year :
- 2013
-
Abstract
- Abstract: The maintenance and repair of reinforced concrete structures, especially those submerged in the sea-water require effective inspection and monitoring techniques for assessing the state of corrosion in the reinforcement material. An underwater inspection system was developed which is able to monitor the corrosion of the reinforcement. The system is composed of a remotely operating vehicle (ROV) equipped with the sealed tube neutron generator (NG). By rotating the NG and by using the associated alpha particle technique it is possible to measure the concrete cover thickness together with the reinforcing bar diameter. The possibility of estimating the carbon and chloride contents in the concrete was investigated. Iron plates of different thickness, covered by 6 cm thick concrete block, were successfully detected and the thickness of the concrete cover was estimated. In addition, reinforcing bar of one and 3 cm in diameter were identified and measured. All measurements could be performed without cleaning the concrete surface from fouling material. [Copyright &y& Elsevier]
Details
- Language :
- English
- ISSN :
- 13504487
- Volume :
- 59
- Database :
- Academic Search Index
- Journal :
- Radiation Measurements
- Publication Type :
- Academic Journal
- Accession number :
- 92655841
- Full Text :
- https://doi.org/10.1016/j.radmeas.2013.06.001