Back to Search Start Over

Liquid–liquid extraction in microchannels with Zinc–D2EHPA system.

Authors :
Darekar, Mayur
Sen, Nirvik
Singh, K.K.
Mukhopadhyay, S.
Shenoy, K.T.
Ghosh, S.K.
Source :
Hydrometallurgy. Apr2014, Vol. 144-145, p54-62. 9p.
Publication Year :
2014

Abstract

Abstract: Liquid–liquid extraction experiments have been carried out in two different types of microchannels using water (Zn) D2EHPA+dodecane system, a standard reactive extraction system recommended for evaluation of liquid–liquid extraction equipment. The microchannels used in the experiments are a t-junction serpentine microchannel and a split and recombine microchannel. Effects of O/A ratio and residence time on overall volumetric mass transfer coefficient have been studied and an attempt has been made to explain the experimental trends with the help of liquid–liquid flow patterns observed by using a high speed image acquisition system. Correlations relating overall volumetric mass transfer coefficients to O/A ratio and velocity are reported for both the microchannels. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
0304386X
Volume :
144-145
Database :
Academic Search Index
Journal :
Hydrometallurgy
Publication Type :
Academic Journal
Accession number :
95389301
Full Text :
https://doi.org/10.1016/j.hydromet.2014.01.010