Back to Search Start Over

High resolution capacitance detection circuit for rotor micro-gyroscope.

Authors :
Ming-Yuan Ren
Hai-Feng Zhang
Xiao-Wei Liu
Zhi-Gang Mao
Source :
AIP Advances. Mar2014, Vol. 4 Issue 3, p031337-1-031337-7. 7p.
Publication Year :
2014

Abstract

Conventional methods for rotor position detection of micro-gyroscopes include common exciting electrodes (single frequency) and common sensing electrodes (frequency multiplex), but they have encountered some problems. So we present a high resolution and low noise pick-off circuit for micro-gyroscopes which utilizes the time multiplex method. The detecting circuit adopts a continuous-time current sensing circuit for capacitance measurement, and its noise analysis of the charge amplifier is introduced. The equivalent output noise power spectral density of phase-sensitive demodulation is 120 nV/Hz1/2. Tests revealed that the whole circuitry has a relative capacitance resolution of 1 × 10-8. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
21583226
Volume :
4
Issue :
3
Database :
Academic Search Index
Journal :
AIP Advances
Publication Type :
Academic Journal
Accession number :
95511491
Full Text :
https://doi.org/10.1063/1.4869239