Back to Search Start Over

Usefulness of Decrease in Oxygen Uptake Efficiency to Identify Gas Exchange Abnormality in Patients with Idiopathic Pulmonary Arterial Hypertension.

Authors :
Tan, Xiaoyue
Yang, Wenlan
Guo, Jian
Zhang, Yan
Wu, Changwei
Sapkota, Rikesh
Kushwaha, Shailendra Prasad
Gong, Sugang
Sun, Xingguo
Liu, Jinming
Source :
PLoS ONE. Jun2014, Vol. 9 Issue 6, p1-8. 8p.
Publication Year :
2014

Abstract

Background: Decline in oxygen uptake efficiency (OUE), especially during exercise, is found in patients with chronic heart failure. In this study we aimed to test the validity and usefulness of OUE in evaluating gas exchange abnormality of patients with idiopathic pulmonary arterial hypertension (IPAH). Methods: We retrospectively investigated the cardiopulmonary exercise test (CPET) with gas exchange measurements in 32 patients with confirmed IPAH. All patients also had resting hemodynamic measurements and pulmonary function test (PFT). Sixteen healthy subjects, matched by age, sex, and body size were used as controls, also had CPET and PFT measurements. Results: In IPAH patients, the magnitude of absolute and percentage of predicted (%pred) oxygen uptake efficiency slope (OUES) and oxygen uptake efficiency plateau (OUEP), as well as several other CPET parameters, were strikingly worse than healthy subjects (P<0.0001). Pattern of changes in OUE in patients is similar to that in controls, In IPAH patients, OUE values at rest, warming up, anaerobic threshold and peak exercise were all significantly lower than in normal (P<0.0001). OUEP%pred, better than OUES%pred, correlated significantly with New York Heart Association (NYHA) functional Class (r = −0.724, P<0.005), Total Pulmonary Vascular Resistance (TPVR) (r = −0.694, P<0.005), diffusing capacity for carbon monoxide (DLCO) (r = 0.577, P<0.05), and the lowest ventilation versus CO2 output ratio during exercise (LowestV˙E/V˙CO2) (r = −0.902, P<0.0001). In addition, the coefficient of variation (COV) of OUEP was lower (20.9%) markedly than OUES (34.3%) (P<0.0001). Conclusions: In patients with IPAH, OUES and OUEP are both significantly lower than the healthy subjects. OUEP is a better physiological parameter than OUES in evaluating the gas exchange abnormality of patients with IPAH. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19326203
Volume :
9
Issue :
6
Database :
Academic Search Index
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
96859338
Full Text :
https://doi.org/10.1371/journal.pone.0098889