Back to Search Start Over

A Meta-Analysis of Randomized Controlled Trials of Low-Volume Polyethylene Glycol plus Ascorbic Acid versus Standard-Volume Polyethylene Glycol Solution as Bowel Preparations for Colonoscopy.

Authors :
Xie, Qingsong
Chen, Linghui
Zhao, Fengqing
Zhou, Xiaohu
Huang, Pengfei
Zhang, Lufei
Zhou, Dongkai
Wei, Jianfeng
Wang, Weilin
Zheng, Shusen
Source :
PLoS ONE. Jun2014, Vol. 9 Issue 6, p1-9. 9p.
Publication Year :
2014

Abstract

Background: Standard-volume polyethylene glycol (PEG) gut lavage solutions are safe and effective, but they require the consumption of large volumes of fluid. A new lower-volume solution of PEG plus ascorbic acid has been used recently as a preparation for colonoscopy. Aim: A meta-analysis was performed to compare the performance of low-volume PEG plus ascorbic acid with standard-volume PEG as bowel preparation for colonoscopy. Study: Electronic and manual searches were performed to identify randomized controlled trials (RCTs) that compared the performance of low-volume PEG plus ascorbic acid with standard-volume PEG as bowel preparation for colonoscopy. After a methodological quality assessment and data extraction, the pooled estimates of bowel preparation efficacy during bowel cleansing, compliance with preparation, willingness to repeat the same preparation, and the side effects were calculated. We calculated pooled estimates of odds ratios (OR) by fixed- and/or random-effects models. We also assessed heterogeneity among studies and the publication bias. Results: Eleven RCTs were identified for analysis. The pooled OR for preparation efficacy during bowel cleansing and for compliance with preparation for low-volume PEG plus ascorbic acid were 1.08 (95% CI = 0.98–1.28, P = 0.34) and 2.23 (95% CI = 1.67–2.98, P<0.00001), respectively, compared with those for standard-volume PEG. The side effects of vomiting and nausea for low-volume PEG plus ascorbic acid were reduced relative to standard-volume PEG. There was no significant publication bias, according to a funnel plot. Conclusions: Low-volume PEG plus ascorbic acid gut lavage achieved non-inferior efficacy for bowel cleansing, is more acceptable to patients, and has fewer side effects than standard-volume PEG as a bowel preparation method for colonoscopy. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19326203
Volume :
9
Issue :
6
Database :
Academic Search Index
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
96859534
Full Text :
https://doi.org/10.1371/journal.pone.0099092