Back to Search Start Over

The direct-drive sensorless generation system for wave energy utilization.

Authors :
Pan, J. F.
Yu Zou
Cheung, Norbert
Guangzhong Cao
Source :
International Journal of Electrical Power & Energy Systems. Nov2014, Vol. 62, p29-37. 9p.
Publication Year :
2014

Abstract

A direct-drive generator based on linear switched reluctance principle is investigated for wave energy utilization. Integrated with the sensorless technique, the direct-drive generator has the characteristics of low cost and robustness, and the power generation control system is especially suitable for the operation under hostile working environments since restrictions of physical sensors are eliminated. Simulation analysis based on the finite element methods (FEM) and joint simulation are carried out for performance analysis of the power generation control system, including position estimation, open loop turn-on and turn-off position optimization and closed loop current regulation. Experimental results validate the effectiveness of the position estimation scheme for the sensorless, linear switched reluctance generator based power generation control system. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01420615
Volume :
62
Database :
Academic Search Index
Journal :
International Journal of Electrical Power & Energy Systems
Publication Type :
Academic Journal
Accession number :
97000522
Full Text :
https://doi.org/10.1016/j.ijepes.2014.04.017