Back to Search
Start Over
Electrical reliability of dc-operated submarine telecommunications cables.
- Source :
-
IEEE Transactions on Dielectrics & Electrical Insulation . Feb97, Vol. 4 Issue 1, p1. 9p. 1 Black and White Photograph, 3 Charts, 9 Graphs. - Publication Year :
- 1997
-
Abstract
- Reports on the results of the research program carried out to quantify the reliability of joint moldings for direct current (dc) operation in submarine telecommunications cables. Microtome sections; Joint moldings of same insulation materials for microtome sections; Moldings of different design and insulation materials; Test procedure for system's reliability; Quality assurance requirements; Conclusions.
Details
- Language :
- English
- ISSN :
- 10709878
- Volume :
- 4
- Issue :
- 1
- Database :
- Academic Search Index
- Journal :
- IEEE Transactions on Dielectrics & Electrical Insulation
- Publication Type :
- Academic Journal
- Accession number :
- 9704302291
- Full Text :
- https://doi.org/10.1109/94.590853