Liquid chromatography-fast atom bombardment mass spectrometry for detection and determination of pentazocine in human tissues.
- Source :
-
Journal of chromatography. B, Biomedical sciences and applications [J Chromatogr B Biomed Sci Appl] 1999 Aug 06; Vol. 731 (1), pp. 149-54. - Publication Year :
- 1999
-
Abstract
- A reliable and sensitive method was developed for the detection and determination of pentazocine in human solid tissues using liquid chromatography-dynamic fast atom bombardment (FAB) mass spectrometry, combined with a three-step liquid-liquid extraction procedure. Levallorphan tartrate served as an internal standard. The extract was evaporated to dryness and dissolved in the mobile phase, acetonitrile-10 mM ammonium acetate solution (20:80, pH 4.0) containing 0.5% glycerol as FAB matrix. The eluent was pumped at a flow rate of 25 microl/min and split before introduction to FAB mass spectrometer. Quantitative analysis was carried out by means of monitoring quasi-molecular ions with m/z 286 for pentazocine and m/z 284 for levallorphan. The lower limit of detection of pentazocine in each tissue tested was 1 ng/g with scan mode and 0.1 ng/g with SIM mode. Using this method, the concentrations of pentazocine were determined in the tissues of an autopsied individual to perform toxicological evaluation.
Details
- Language :
- English
- ISSN :
- 1387-2273
- Volume :
- 731
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Journal of chromatography. B, Biomedical sciences and applications
- Publication Type :
- Academic Journal
- Accession number :
- 10492001
- Full Text :
- https://doi.org/10.1016/s0378-4347(99)00152-8