Back to Search Start Over

Application of ion-exchange cartridge clean-up in food analysis. II. Determination of benzylpenicillin, phenoxymethylpenicillin, oxacillin, cloxacillin, nafcillin and dicloxacillin in meat using liquid chromatography with ultraviolet detection.

Authors :
Ito Y
Ikai Y
Oka H
Kagami T
Takeba K
Source :
Journal of chromatography. A [J Chromatogr A] 1999 Sep 03; Vol. 855 (1), pp. 247-53.
Publication Year :
1999

Abstract

A multiresidue analytical method was developed for the simultaneous determination of benzylpenicillin (PCG), phenoxymethylpenicillin (PCV), oxacillin (MPIPC), cloxacillin (MCIPC), nafcillin (NFPC) and dicloxacillin (MDIPC) in meat. The method involves the use of an ion-exchange cartridge for sample clean-up followed by ion-pair high-performance liquid chromatography with ultraviolet detection. The recoveries of PCG, PCV, MPIPC, MCIPC, NFPC and MDIPC from pork muscle spiked at levels of 0.5, 0.1 and 0.05 mg/kg were in the range of 77-90, 73-95 and 80-93% with coefficients of variation of 0.5-1.7, 1.6-4.4 and 3.2-6.6%, respectively. For beef muscle spiked at levels of 0.5, 0.1 and 0.05 mg/kg, the recoveries of these compounds were 83-92, 71-86 and 77-90% with coefficients of variation of 1.7-4.4, 2.6-7.0 and 3.9-6.4%, respectively. The detection limits for each penicillin were 0.02 mg/kg in meat.

Details

Language :
English
ISSN :
0021-9673
Volume :
855
Issue :
1
Database :
MEDLINE
Journal :
Journal of chromatography. A
Publication Type :
Academic Journal
Accession number :
10514989