Back to Search
Start Over
Approach to patients with long-term weaning failure.
- Source :
-
Respiratory care clinics of North America [Respir Care Clin N Am] 2000 Sep; Vol. 6 (3), pp. 437-61;vi. - Publication Year :
- 2000
-
Abstract
- Efforts to treat reversible disease processes that contribute to ventilator dependency in the intensive care unit (ICU) fail in up to 20% of patients, resulting in prolonged mechanical ventilation (PMV). Resolution of the insults that necessitated ICU admission and mechanical ventilation may be incomplete, and the economic pressure to transfer patients is ever increasing. The choice of post-ICU disposition depends on the patient's clinical condition, the resources of the transfer destination, and whether weaning attempts will continue. This article reviews data from a decade of weaning beyond the ICU, including outcomes of more than 2700 patients with PMV afforded continued attempts at liberation in long-term acute care facilities and other post-ICU weaning venues. Assessment and treatment, weaning strategies, and complications of patients with PMV are described.
Details
- Language :
- English
- ISSN :
- 1078-5337
- Volume :
- 6
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Respiratory care clinics of North America
- Publication Type :
- Academic Journal
- Accession number :
- 10899265
- Full Text :
- https://doi.org/10.1016/s1078-5337(05)70080-0