Detection of Legionella pneumophila using a real-time PCR hybridization assay.

Authors :
Ballard AL
Fry NK
Chan L
Surman SB
Lee JV
Harrison TG
Towner KJ
Source :
Journal of clinical microbiology [J Clin Microbiol] 2000 Nov; Vol. 38 (11), pp. 4215-8.
Publication Year :
2000

Abstract

A real-time PCR hybridization assay for Legionella pneumophila is described; the assay uses LightCycler (Idaho Technology) methodology to specifically detect 2.5 CFU/reaction, equivalent to 1,000 CFU/liter of starting water sample. The assay, including DNA extraction and confirmation of product identity, is completed within 90 min of receipt of a sample.