Sensitive determination of diquat by a kinetic method using the stopped-flow mixing technique.

Authors :
Pérez-Ruiz T
Martínez-Lozano C
Tomás V
Fenoll J
Source :
The Analyst [Analyst] 2000 Dec; Vol. 125 (12), pp. 2372-5.
Publication Year :
2000

Abstract

A simple, sensitive, selective, fast and inexpensive assay for the determination of diquat is proposed. The method is based on the reduction of the herbicide to a strongly fluorescent monocation radical with sodium dithionite. The initial rate of this reaction is directly proportional to the diquat concentration. The stopped-flow mixing technique was used because the kinetic data can be obtained in only 7 s, meaning that the method can be automated. The calibration graph is linear over the range 5-500 ng ml-1 and the precision (RSD) is close to 1.2%. The applicability of the method was demonstrated by determining the herbicide in different kinds of samples.