Back to Search
Start Over
Quantification of nimesulide in human plasma by high-performance liquid chromatography/tandem mass spectrometry. Application to bioequivalence studies.
- Source :
-
Journal of mass spectrometry : JMS [J Mass Spectrom] 2001 Dec; Vol. 36 (12), pp. 1281-6. - Publication Year :
- 2001
-
Abstract
- A method based on liquid chromatography with negative ion electrospray ionization and tandem mass spectrometry is described for the determination of nimesulide in human plasma. Liquid-liquid extraction using a mixture of diethyl ether and dichloromethane was employed and celecoxib was used as an internal standard. The chromatographic run time was 4.5 min and the weighted (1/x) calibration curve was linear in the range 10.0-2000 ng x ml(-1). The limit of quantification was 10 ng x ml(-1), the intra-batch precision was 6.3, 2.1 and 2.1% and the intra-batch accuracy was 3.2, 0.3 and 0.1% for 30, 300 and 1200 ng x ml(-1) respectively. The inter-batch precision was 2.3, 2.8 and 2.7% and the accuracy was 3.3, 0.3 and 0.1% for 30, 300 and 1200 ng x ml(-1) respectively. This method was employed in a bioequivalence study of one nimesulide drop formulation (nimesulide 50 mg x ml(-1) drop, Medley S/A Indústria Farmacêutica, Brazil) against one standard nimesulide drop formulation (Nisulid, 50 mg x ml(-1) drop, Astra Médica, Brazil). Twenty-four healthy volunteers (both sexes) took part in the study and received a single oral dose of nimesulide (100 mg, equivalent to 2 ml of either formulation) in an open, randomized, two-period crossover way, with a 2-week washout interval between periods. The 90% confidence interval (CI) for geometric mean ratios between nimesulide and Nisulid were 93.1-109.6% for C(max), 87.7-99.8% for AUC(last) and 88.1-99.7% for AUC(0-infinity). Since the 90% CI for the above-mentioned parameters were included in the 80-125% interval proposed by the US Food and Drug Administration, the two formulations were considered bioequivalent in terms of both rate and extent of absorption.<br /> (Copyright 2001 John Wiley & Sons, Ltd.)
- Subjects :
- Adolescent
Adult
Drug Stability
Ether
Female
Humans
Male
Methylene Chloride
Middle Aged
Quality Control
Sensitivity and Specificity
Sulfonamides administration & dosage
Sulfonamides pharmacokinetics
Chromatography, High Pressure Liquid methods
Mass Spectrometry methods
Sulfonamides blood
Therapeutic Equivalency
Subjects
Details
- Language :
- English
- ISSN :
- 1076-5174
- Volume :
- 36
- Issue :
- 12
- Database :
- MEDLINE
- Journal :
- Journal of mass spectrometry : JMS
- Publication Type :
- Academic Journal
- Accession number :
- 11754119
- Full Text :
- https://doi.org/10.1002/jms.232