Back to Search
Start Over
Direct identification and susceptibility testing of enteric bacilli from positive blood cultures using VITEK (GNI+/GNS-GA).
- Source :
-
Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases [Clin Microbiol Infect] 2002 Jan; Vol. 8 (1), pp. 38-44. - Publication Year :
- 2002
-
Abstract
- Objective: To study the possibility of reporting results of identification and susceptibility testing of Gram-negative bacilli the same day as bacteremia is detected by using direct inoculation from positive blood cultures (Bactec 9240) into VITEK GNI+ and GNS-GA cards.<br />Methods: All blood cultures with Gram-negative enteric bacillus-like morphology on microscopy found to be positive on workdays between 15 June 1999 and 29 February 2000 were included. Identification and susceptibility testing were done by three methods: the direct method using a suspension made by differential centrifugation of positive blood culture broth for inoculation of the VITEK cards; the standard method using an inoculum made from an overnight culture on a solid media; and the routine method (reference method) using conventional testing.<br />Results: Of 169 isolates, the direct method resulted in 75% correct identifications, 9% misidentifications and 17% non-identifications. All misidentified isolates were Escherichia coli, of which 80% were reported as Salmonella arizonae. Five biochemical tests yielded most of the aberrant results; correcting the citrate and malonate reactions in most cases led to correct identification by the VITEK database. Despite a negative H2S reaction, 11 E. coli isolates were reported as S. arizonae. Two-thirds (69%) of identifications were reported within 6 h, and 95% of these were correct. The direct susceptibility testing method was assessable for 140 isolates. Correct results were found in 99% of isolate-antimicrobial combinations, and 85% were reported within 6 h.<br />Conclusion: The direct VITEK method could correctly report identifications and susceptibility patterns within 6 h, making same-day reporting possible for almost two-thirds (63%) of bacteremic episodes with Gram-negative bacilli. These results could probably be improved by modification of the identification algorithms of the VITEK software.
- Subjects :
- Bacteremia diagnosis
Enterobacteriaceae drug effects
Enterobacteriaceae Infections microbiology
Escherichia coli drug effects
Escherichia coli isolation & purification
Humans
Salmonella isolation & purification
Salmonella arizonae drug effects
Salmonella arizonae isolation & purification
Software
Bacteriological Techniques
Enterobacteriaceae isolation & purification
Enterobacteriaceae Infections diagnosis
Microbial Sensitivity Tests methods
Subjects
Details
- Language :
- English
- ISSN :
- 1198-743X
- Volume :
- 8
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases
- Publication Type :
- Academic Journal
- Accession number :
- 11906499
- Full Text :
- https://doi.org/10.1046/j.1469-0691.2002.00372.x