Back to Search
Start Over
A rapid assay method for catechol-O-methyltransferase activity by flow injection analysis.
- Source :
-
Biomedical chromatography : BMC [Biomed Chromatogr] 2002 Jun; Vol. 16 (4), pp. 255-60. - Publication Year :
- 2002
-
Abstract
- A rapid assay employing flow injection analysis (FIA) to determine the activity of purified catechol-O-methyltransferase (COMT) from porcine liver is described. The method was based on the determination of normetanephrine, the 3-O-methyl metabolite of the substrate norepinephrine. Excess norepinephrine was removed from the incubation mixture by alumina extraction twice to allow normetanephrine to be subjected to flow injection analysis, coulometrical oxidation, fluorogenic reaction with ethylenediamine and fluorescence detection. K(m) and V(max) values for COMT obtained with the system were 503 microM and 4.51 nmol/min/mg protein, respectively. The method is suitable for screening of COMT inhibitors or activators, as a large number of samples, up to 200, can be processed in one working day.<br /> (Copyright 2002 John Wiley & Sons, Ltd.)
Details
- Language :
- English
- ISSN :
- 0269-3879
- Volume :
- 16
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Biomedical chromatography : BMC
- Publication Type :
- Academic Journal
- Accession number :
- 11933025
- Full Text :
- https://doi.org/10.1002/bmc.156