Back to Search Start Over

Dose estimation using quartz OSL in the non-linear region of the growth curve.

Authors :
Murray AS
Wintle AG
Wallinga J
Source :
Radiation protection dosimetry [Radiat Prot Dosimetry] 2002; Vol. 101 (1-4), pp. 371-4.
Publication Year :
2002

Abstract

The reliability of equivalent-dose determinations on quartz made with the single-aliquot regenerative-dose (SAR) protocol is examined using a suite of sedimentary samples for which the equivalent dose is expected to be >200 Gy. Experiments on one sample were used to evaluate the precision obtained using the standard measurement procedure with (a) a range of pre-heat temperatures, and (b) a single pre-heat temperature. The precision is compared with that achieved using SAR for a repeated dose point after an initial pre-heat, and for a known dose given before the initial pre-heat. It is concluded that, at least for this sample, the scatter in OSL measurements dominates the spread in the estimates of De.

Details

Language :
English
ISSN :
0144-8420
Volume :
101
Issue :
1-4
Database :
MEDLINE
Journal :
Radiation protection dosimetry
Publication Type :
Academic Journal
Accession number :
12382770
Full Text :
https://doi.org/10.1093/oxfordjournals.rpd.a006004