Colonic perforation complicating posteroanterior fusion using fibular strut autograft for a high-grade spondylolisthesis.

Authors :
Shindle MK
Khanna AJ
Hoehner JC
O'Neill PJ
Sponseller PD
Source :
Journal of spinal disorders & techniques [J Spinal Disord Tech] 2002 Dec; Vol. 15 (6), pp. 546-9.
Publication Year :
2002

Abstract

Posteroanterior fusion using a fibular strut autograft has been advocated for the surgical treatment of high-grade lumbosacral spondylolisthesis. We report here the treatment of a 14-year-old girl using an S2-L5 fibular autograft, which resulted in the postoperative complication of a sigmoid colon perforation. Techniques for recognizing, treating, and avoiding this complication are presented.