Back to Search Start Over

[MR angiography of the coronary arteries: comparison of the blood pool contrast medium Gadomer and Gd-DTPA in pigs].

Authors :
Schnorr J
Wagner S
Ebert W
Heyer C
Laub G
Kivelitz D
Abramjuk C
Hamm B
Taupitz M
Source :
RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin [Rofo] 2003 Jun; Vol. 175 (6), pp. 822-9.
Publication Year :
2003

Abstract

Aim: To investigate the signal-enhancing effects of the macromolecular contrast medium Gadomer in MR angiography of the coronary arteries compared to Gd-DTPA.<br />Material and Methods: A total of 15 MRI examinations of the heart were performed in pigs at 1.5 T using a pulse-triggered, segmented 3D FLASH sequence with data acquisition during breathhold before and up to 30 min after contrast medium injection. Gadomer was investigated at two doses (0.05 and 0.1 mmol Gd/kg), Gd-DTPA at one (0.3 mmol Gd/kg) (n = 5 examinations per dose). Standard sequences without magnetization preparation were supplemented by sequences with magnetization saturation applied before data acquisition before and immediately after contrast medium injection. Analysis comprised quantitative determination of blood and myocardium signal to noise (S/N) and contrast to noise (C/N) and qualitative assessment of several parameters of image quality and coronary artery visualization.<br />Results: Gadomer leads to a significant C/N increase between blood and myocardium compared to the unenhanced examination and the increase is longer-lasting than that produced by Gd-DTPA (Gd-DTPA: only directly after injection; Gadomer: up to 5 min post injection at 0.05 mmol Gd/kg, up to 10 min at 0.1 mmol Gd/kg). The qualitative evaluation shows that visualization of the coronary arteries and branch vessels is significantly better with Gadomer at both doses than with Gd-DTPA. Magnetization saturation increases the C/N in combination with Gd-DTPA and at the higher dose of Gadomer with the latter producing a higher increase in C/N values.<br />Conclusion: Gadomer is a suitable contrast medium for MR angiography of the coronary arteries with the dose of 0.1 mmol Gd/kg being superior to 0.05 mmol Gd/kg due to a longer imaging window.

Details

Language :
German
ISSN :
1438-9029
Volume :
175
Issue :
6
Database :
MEDLINE
Journal :
RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin
Publication Type :
Academic Journal
Accession number :
12811696
Full Text :
https://doi.org/10.1055/s-2003-39931