- Aim: To investigate the signal-enhancing effects of the macromolecular contrast medium Gadomer in MR angiography of the coronary arteries compared to Gd-DTPA.<br />Material and Methods: A total of 15 MRI examinations of the heart were performed in pigs at 1.5 T using a pulse-triggered, segmented 3D FLASH sequence with data acquisition during breathhold before and up to 30 min after contrast medium injection. Gadomer was investigated at two doses (0.05 and 0.1 mmol Gd/kg), Gd-DTPA at one (0.3 mmol Gd/kg) (n = 5 examinations per dose). Standard sequences without magnetization preparation were supplemented by sequences with magnetization saturation applied before data acquisition before and immediately after contrast medium injection. Analysis comprised quantitative determination of blood and myocardium signal to noise (S/N) and contrast to noise (C/N) and qualitative assessment of several parameters of image quality and coronary artery visualization.<br />Results: Gadomer leads to a significant C/N increase between blood and myocardium compared to the unenhanced examination and the increase is longer-lasting than that produced by Gd-DTPA (Gd-DTPA: only directly after injection; Gadomer: up to 5 min post injection at 0.05 mmol Gd/kg, up to 10 min at 0.1 mmol Gd/kg). The qualitative evaluation shows that visualization of the coronary arteries and branch vessels is significantly better with Gadomer at both doses than with Gd-DTPA. Magnetization saturation increases the C/N in combination with Gd-DTPA and at the higher dose of Gadomer with the latter producing a higher increase in C/N values.<br />Conclusion: Gadomer is a suitable contrast medium for MR angiography of the coronary arteries with the dose of 0.1 mmol Gd/kg being superior to 0.05 mmol Gd/kg due to a longer imaging window.
- Subjects :
- Animals
Artifacts
Contrast Media pharmacokinetics
Dose-Response Relationship, Drug
Drug Evaluation, Preclinical
Injections, Intravenous
Metabolic Clearance Rate physiology
Sensitivity and Specificity
Swine
Swine, Miniature
Contrast Media administration & dosage
Coronary Disease diagnosis
Coronary Vessels pathology
Gadolinium pharmacokinetics
Gadolinium DTPA pharmacokinetics
Magnetic Resonance Angiography methods
Subjects
Details
- Language :
- German
- ISSN :
- 1438-9029
- Volume :
- 175
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin
- Publication Type :
- Academic Journal
- Accession number :
- 12811696
- Full Text :
- https://doi.org/10.1055/s-2003-39931