[Determination of Pb, Zn, Fe and Cd in the crude zinc produced from the imperial smelting furnace by XRF].

Authors :
Chen CQ
Deng LP
Source :
Guang pu xue yu guang pu fen xi = Guang pu [Guang Pu Xue Yu Guang Pu Fen Xi] 2001 Oct; Vol. 21 (5), pp. 670-2.
Publication Year :
2001

Abstract

This paper covers the determination of Pb, Zn Fe and Cd in the crude zinc produced from the imperial smelting furnace by XRF. Samples of crude zinc are taken on site and cast into ingots of definite shape. The analysed surface of the sample is polished and analysed directly without chemical treatment. The experience coefficient method is used to calibrate the matrix effect. Standard samples are prepared by artificial simulation. The linear relation coefficient between the concentration and the strength of X-ray is above 0.98. The standard deviation is less than 0.0056. The relative standard deviation is less than 2.41%. The results by XRF are the same as that by chemical analysis method.

Details

Language :
Chinese
ISSN :
1000-0593
Volume :
21
Issue :
5
Database :
MEDLINE
Journal :
Guang pu xue yu guang pu fen xi = Guang pu
Publication Type :
Academic Journal
Accession number :