Back to Search Start Over

Detection of Mycoplasma pneumoniae in respiratory samples by real-time PCR using an inhibition control.

Authors :
Ursi D
Dirven K
Loens K
Ieven M
Goossens H
Source :
Journal of microbiological methods [J Microbiol Methods] 2003 Oct; Vol. 55 (1), pp. 149-53.
Publication Year :
2003

Abstract

Polymerase chain reaction (PCR) with real-time detection using two adjacent fluorescent probes in a Lightcycler instrument was applied for detection of the Mycoplasma pneumoniae P1 protein gene. To monitor inhibition in each sample an internal control was constructed that can be amplified by the same primers but detected by different probes and dual color detection. The real-time PCR was applied on 115 respiratory samples from 82 patients and compared to a conventional PCR. There was 100% agreement between the assays, but the real-time PCR proved to be highly superior in speed with a much lower risk of false positives by laboratory contamination.

Details

Language :
English
ISSN :
0167-7012
Volume :
55
Issue :
1
Database :
MEDLINE
Journal :
Journal of microbiological methods
Publication Type :
Academic Journal
Accession number :
14500006
Full Text :
https://doi.org/10.1016/s0167-7012(03)00131-3