Back to Search Start Over

Preliminary evaluation of a fuzzy logic-based automatic quantitative analysis in myocardial SPECT.

Authors :
Cachin F
Lipiecki J
Mestas D
Amonchot A
Geissler B
Thouly C
Ponsonnaille J
Maublant J
Source :
Journal of nuclear medicine : official publication, Society of Nuclear Medicine [J Nucl Med] 2003 Oct; Vol. 44 (10), pp. 1625-32.
Publication Year :
2003

Abstract

Unlabelled: This study validates a new quantitative myocardial perfusion SPECT software.<br />Methods: The processing starts with the extraction of the morphologic skeleton of the left ventricular myocardium from reconstructed transverse sections. Fuzzy logic is used to decide whether a pixel belongs to the myocardium and any perfusion defect is filled according to a truncated bullet model. The resulting image is partitioned in 18 isovolumetric sectors. Sex-matched normal limits, criteria of abnormality for rest (201)Tl and (99m)Tc-labeled perfusion tracers, reproducibility studies, and detection of coronary artery disease were developed and validated in an overall population of 343 patients. The sex- and tracer-matched means and SDs of a normal response were calculated in 93 male and 93 female patients with a <5% likelihood of coronary artery disease. Reproducibility measurements and assignment of different sectors of the myocardium to a specific coronary were performed from data collected in 49 and 60 patients, respectively. The accuracy of the detection of a coronary artery occlusion was assessed in 48 patients who also underwent coronary angiography.<br />Results: The intra- and interoperator reproducibility of the sectorial activity was high with a linear regression coefficient of 0.97 and a SD of the difference measurement at 4.4% and 3.8%, respectively. Overall sensitivity and specificity for the detection of occluded coronary artery were 90% and 80%, respectively. For the detection of left anterior descending, left circumflex, and right artery coronary occlusion, sensitivity was 92%, 75%, and 92.5%, respectively, and specificity was 75%, 78%, and 90%, respectively.<br />Conclusion: The new quantitative myocardial perfusion SPECT software appears to be a very helpful program for the objective analysis of perfusion tracer distribution in myocardial SPECT and a very accurate tool in the detection and localization of coronary artery occlusion.

Details

Language :
English
ISSN :
0161-5505
Volume :
44
Issue :
10
Database :
MEDLINE
Journal :
Journal of nuclear medicine : official publication, Society of Nuclear Medicine
Publication Type :
Academic Journal
Accession number :
14530477