Back to Search Start Over

Validation of a confirmatory method for the determination of sulphonamides in muscle according to the European Union regulation 2002/657/EC.

Authors :
Pecorelli I
Bibi R
Fioroni L
Galarini R
Source :
Journal of chromatography. A [J Chromatogr A] 2004 Apr 02; Vol. 1032 (1-2), pp. 23-9.
Publication Year :
2004

Abstract

A simple multiresidue method is described for assaying 10 sulphonamides (SAs) (sulfadiazine, sulfathiazole, sulfapyridine, sulfamerazine, sulfamethazine, sulfamonomethoxine, sulfachlorpyridazine, sulfamethoxazole, sulfaquinoxaline and sulfadimethoxine) in muscle samples. Samples were prepared by homogenizing the tissue, extracting with ethyl acetate and cleaning up with a cation-exchange solid-phase extraction (SPE) column. The detection of analytes was achieved by HPLC-diode array detection (DAD) at 270 nm. The procedure was validated according to the European Union regulation 2002/657/EC determining specificity, decision limit, detection capability, trueness and precision. The results of validation process demonstrate that the method is suitable for application in European Union statutory veterinary drug residue surveillance programmes.

Details

Language :
English
ISSN :
0021-9673
Volume :
1032
Issue :
1-2
Database :
MEDLINE
Journal :
Journal of chromatography. A
Publication Type :
Academic Journal
Accession number :
15065772
Full Text :