Back to Search
Start Over
Intra-laboratory analytical variability of biochemical markers of fibrosis (Fibrotest) and activity (Actitest) and reference ranges in healthy blood donors.
- Source :
-
Clinical chemistry and laboratory medicine [Clin Chem Lab Med] 2004 Mar; Vol. 42 (3), pp. 323-33. - Publication Year :
- 2004
-
Abstract
- Combinations of tests comprising alpha2-macroglobulin, haptoglobin, apolipoprotein Al, gamma-glutamyltransferase, total bilirubin (Fibrotest) and alanine aminotransferase (Actitest) are being developed as alternatives to liver biopsy in patients with chronic hepatitis C. The aim of this study was to assess in the same laboratory the impact of parameter assay variations on Fibrotest and Actitest results and intra-patient reproducibility of the two tests. The stability of the samples for each test was studied after storage at -80 degrees C and -20 degrees C. Within-run, between-run and total imprecision for each parameter assay, and for Fibrotest and Actitest results, were determined. Transferability of assay results between different analyzers was studied. Intra-patient reproducibility was assessed in 55 hospitalized patients. Fibrotest and Actitest reference ranges were determined in 300 blood donors (reference group). The stability of the parameters was affected by serum storage at -20 degrees C only. The impact of parameter analytical variability on Fibrotest and Actitest results was less than 10% and intra-patient reproducibility was acceptable (p > 0.05). The transferability between different analyzers of results of assays performed under the same standardized and calibration conditions was excellent. Fibrotest and Actitest reference ranges in blood donors were (mean+/-SE) 0.075+/-0.004 and 0.068+/-0.004, respectively. The low intra-laboratory and intra-patient variability in Fibrotest and Actitest results confirm Fibrotest and Actitest reliability.
- Subjects :
- Age Factors
Alanine Transaminase blood
Analysis of Variance
Apolipoprotein A-I blood
Apolipoprotein A-I chemistry
Bilirubin blood
Bilirubin chemistry
Biomarkers blood
Blood Donors
Body Mass Index
Clinical Chemistry Tests instrumentation
Clinical Chemistry Tests standards
Confidence Intervals
Diagnostic Tests, Routine instrumentation
Diagnostic Tests, Routine standards
Diagnostic Tests, Routine statistics & numerical data
Enzyme Stability
Fibrosis
Freezing
Haptoglobins analysis
Haptoglobins chemistry
Humans
Reference Values
Reproducibility of Results
Sex Factors
Temperature
alpha-Macroglobulins analysis
alpha-Macroglobulins chemistry
gamma-Glutamyltransferase blood
gamma-Glutamyltransferase chemistry
Clinical Chemistry Tests statistics & numerical data
Hepatitis C, Chronic blood
Subjects
Details
- Language :
- English
- ISSN :
- 1434-6621
- Volume :
- 42
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Clinical chemistry and laboratory medicine
- Publication Type :
- Academic Journal
- Accession number :
- 15080567
- Full Text :
- https://doi.org/10.1515/CCLM.2004.058