Effect of perfusion pattern and imaging sequence on gated perfusion SPECT evaluation of myocardial stunning.
- Source :
-
Journal of nuclear medicine : official publication, Society of Nuclear Medicine [J Nucl Med] 2005 Jan; Vol. 46 (1), pp. 176-83. - Publication Year :
- 2005
-
Abstract
- Unlabelled: The aim of this study was to determine the effect of perfusion defect and imaging sequence on the evaluation of myocardial stunning with gated perfusion SPECT.<br />Methods: A dynamic mathematic cardiac torso phantom was used to create 100 gated SPECT simulations (50 stress-rest and 50 rest-stress sequences) with a wide range of perfusion defects. No segmental wall motion abnormalities were created. After generating projection images, 2 additional acquisitions were simulated by thresholding the projected data to 25% and 75% of the maximum. Finally, gated SPECT projections were grouped by 2s to generate 2 series of phantoms corresponding to stress-rest and rest-stress imaging sequences. For each sequence, the first dataset was the 25% thresholded gated SPECT. Both 75% thresholded and 100% signal intensity were used as a second dataset. Each simulated gated SPECT image differed from others in the extent of myocardial scar or ischemia, but all had the same end-diastolic volume (EDV) (125 mL), end-systolic volume (ESV) (48 mL), and ejection fraction (EF) (62%). Left ventricular perfusion and function were each assessed using validated software.<br />Results: Mean stress EDV was decreased when compared with rest-simulated data (111 +/- 4.7 and 112.4 +/- 4.8 mL, respectively; P < or = 0.05), and mean stress ESV was increased when compared with rest-simulated data (44 +/- 4.2 and 42.7 +/- 4 mL, respectively; P < 0.02). The resulting mean stress EF was decreased in the same comparison (60.3% +/- 3.1% and 62% +/- 2.7%, respectively; P = 0.0001). After multivariate analysis, the difference between stress and rest EF was significantly influenced by myocardial infarction (P = 0.0027), severe extent of myocardial ischemia (P = 0.0017), and imaging sequence (P < 0.0001). A > or =5% decrease in EF on stress SPECT (i.e., myocardial stunning) was significantly associated with the stress-rest sequence (chi(2) = 26; P < 0.0001).<br />Conclusion: Perfusion defects and imaging sequence had significant effects on the evaluation of myocardial stunning using gated perfusion SPECT.
- Subjects :
- Algorithms
Computer Simulation
Exercise Test
Gated Blood-Pool Imaging instrumentation
Humans
Imaging, Three-Dimensional methods
Myocardial Stunning complications
Phantoms, Imaging
Reproducibility of Results
Sensitivity and Specificity
Severity of Illness Index
Tomography, Emission-Computed, Single-Photon instrumentation
Ventricular Dysfunction, Left etiology
Gated Blood-Pool Imaging methods
Image Interpretation, Computer-Assisted methods
Models, Cardiovascular
Myocardial Stunning diagnostic imaging
Tomography, Emission-Computed, Single-Photon methods
Ventricular Dysfunction, Left diagnostic imaging
Subjects
Details
- Language :
- English
- ISSN :
- 0161-5505
- Volume :
- 46
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
- Publication Type :
- Academic Journal
- Accession number :
- 15632050