Back to Search Start Over

Amperometric detection in TMB/HRP-based assays.

Authors :
Fanjul-Bolado P
González-García MB
Costa-García A
Source :
Analytical and bioanalytical chemistry [Anal Bioanal Chem] 2005 May; Vol. 382 (2), pp. 297-302. Date of Electronic Publication: 2005 May 13.
Publication Year :
2005

Abstract

3,3',5,5'-Tetramethylbenzidine (TMB) is the most commonly used chromogen for horseradish peroxidase (HRP) and so its performance as an electrochemical substrate was evaluated. Measurements of HRP activity in solution were carried out by using an amperometric detector coupled to a flow injection analysis (FIA) system. The enzymatic product was easily detected at a potential of +0.1 V (vs. Ag-pseudoreference electrode) at a bare screen-printed electrode placed in a homemade electrochemical flow cell. A high flow rate (4.3 mL min(-1)) of 0.5 M H2SO4 was used to obtain repeatable signals and a short analysis time. The detection limit achieved after 15 min of incubation was 2x10(-14) M of HRP. The applicability of the amperometric detector to ELISAs was demonstrated by using a commercially available kit for the quantification of interleukin-6 (IL-6) without modifying the kit manufacturer's protocol or the reagents for this test.

Details

Language :
English
ISSN :
1618-2642
Volume :
382
Issue :
2
Database :
MEDLINE
Journal :
Analytical and bioanalytical chemistry
Publication Type :
Academic Journal
Accession number :
15891870
Full Text :
https://doi.org/10.1007/s00216-005-3084-9