Back to Search Start Over

Cortical T2 signal shortening in amyotrophic lateral sclerosis is not due to iron deposits.

Authors :
Hecht MJ
Fellner C
Schmid A
Neundörfer B
Fellner FA
Source :
Neuroradiology [Neuroradiology] 2005 Nov; Vol. 47 (11), pp. 805-8. Date of Electronic Publication: 2005 Sep 21.
Publication Year :
2005

Abstract

Signal shortening of the motor cortex in T2-weighted MR images is a frequent finding in patients with amyotrophic lateral sclerosis (ALS). The cause of signal shortening in ALS is unknown, although iron deposits have been suggested. To test this hypothesis, we acquired T2*-weighted gradient-echo (GRE) MR images in addition to T2-weighted turbo spin-echo in 69 patients with ALS. Signal shortening in T2-weighted images was found in 31 patients. In T2*-weighted GRE images, only three patients had signal shortening. One patient with additional bifrontal haemorrhage had frontal but no motor cortex signal shortening. Iron deposits do not cause cortical signal shortening in patients with ALS predominantly. Other factors are presumably more important in the generation of cortical T2 shortening in ALS.

Details

Language :
English
ISSN :
0028-3940
Volume :
47
Issue :
11
Database :
MEDLINE
Journal :
Neuroradiology
Publication Type :
Academic Journal
Accession number :
16175348
Full Text :
https://doi.org/10.1007/s00234-005-1421-5