Back to Search
Start Over
Quantitative determination of guanidinoacetate and creatine in dried blood spot by flow injection analysis-electrospray tandem mass spectrometry.
- Source :
-
Clinica chimica acta; international journal of clinical chemistry [Clin Chim Acta] 2006 Feb; Vol. 364 (1-2), pp. 180-7. Date of Electronic Publication: 2005 Sep 28. - Publication Year :
- 2006
-
Abstract
- Background: Guanidinoacetate (GAA) and creatine (Cr) are reliable biochemical markers of primary creatine disorders. The aim of this study was to develop and validate a method for the determination of GAA and Cr in dried blood spot through the use of stable isotope dilution and flow injection analysis (FIA)-ESI-MS/MS.<br />Methods: Dried blood spots were extracted using methanol-water solution containing D3-Cr. After evaporation and formation of butyl esters, samples were analyzed using multiple reaction monitoring mode (m/z 174.2-->101.1 for GAA, 188.3-->90.1 for Cr and 191.3-->93.1 for D3-Cr).<br />Results: The analysis was very fast (1 min). The detection limits were 0.34 micromol/l of blood and 0.30 micromol/l of blood for Cr and GAA, respectively, and the response was linear over the range 0.25-12.5 micromol/l of blood for GAA and 3.57-624.7 micromol/l of blood for Cr. Recovery range was 93-101% for Cr and 94-105% for GAA and between-run CVs were 5.3% for GAA and 4.5% for Cr. Ion suppression effect was also studied. The method was applied to spots obtained from two patients affected by GAMT deficiency, four patients affected by AGAT deficiency (including a newborn) as well as 282 healthy subjects.<br />Conclusions: The detection of GAA in dried blood spot by FIA-ESI-MS/MS is a highly reliable and high throughput method for the diagnosis of GAMT and AGAT deficiencies and a possible tool for newborn screening of both these tractable disorders.
- Subjects :
- Amidinotransferases deficiency
Child
Child, Preschool
Chromatography, High Pressure Liquid
Creatine standards
Glycine blood
Glycine standards
Guanidinoacetate N-Methyltransferase deficiency
Humans
Infant
Infant, Newborn
Nervous System Diseases blood
Nervous System Diseases enzymology
Reference Values
Reproducibility of Results
Spectrometry, Mass, Electrospray Ionization instrumentation
Creatine blood
Glycine analogs & derivatives
Spectrometry, Mass, Electrospray Ionization methods
Subjects
Details
- Language :
- English
- ISSN :
- 0009-8981
- Volume :
- 364
- Issue :
- 1-2
- Database :
- MEDLINE
- Journal :
- Clinica chimica acta; international journal of clinical chemistry
- Publication Type :
- Academic Journal
- Accession number :
- 16197934
- Full Text :
- https://doi.org/10.1016/j.cca.2005.06.016