[Pelvic stabilization in cases of septic instability. Triangular osteosynthesis in case of infection related vertical pelvic ring instability].
- Source :
-
Der Unfallchirurg [Unfallchirurg] 2006 May; Vol. 109 (5), pp. 422-4. - Publication Year :
- 2006
-
Abstract
- The combination of transiliac screws and lumbopelvic distraction osteosynthesis is usually an appropriate procedure to treat vertical pelvic ring instabilities under the condition of full weight bearing. In this case, due to the extent of septic destruction of the dorsal portion of the iliac bone, the common triangular fixation method using conventional pedicle screws was not possible. Using the transiliac dorsoventral screw position with special long screws, we achieved high mechanical triangular stability sufficient for pelvic ring fusion despite the large bony defect.
- Subjects :
- Adult
Bone Plates
Bone Screws
Female
Fracture Fixation, Internal instrumentation
Humans
Magnetic Resonance Imaging
Pseudarthrosis diagnosis
Pseudarthrosis diagnostic imaging
Pseudarthrosis surgery
Punctures
Sepsis complications
Titanium
Tomography, X-Ray Computed
Fracture Fixation, Internal methods
Ilium surgery
Joint Instability etiology
Pelvic Bones surgery
Pseudarthrosis etiology
Sacroiliac Joint diagnostic imaging
Sacrum surgery
Subjects
Details
- Language :
- German
- ISSN :
- 0177-5537
- Volume :
- 109
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Der Unfallchirurg
- Publication Type :
- Academic Journal
- Accession number :
- 16705430
- Full Text :
- https://doi.org/10.1007/s00113-006-1112-7