[A study on axis length measurement of high myopia with cataract].
- Source :
-
Yan ke xue bao = Eye science [Yan Ke Xue Bao] 2005 Dec; Vol. 21 (4), pp. 124-6, 130. - Publication Year :
- 2005
-
Abstract
- Purpose: To study the accuracy of axis length measurement on high myopia with cataract.<br />Methods: A/B scan ultrasonography and IOL-master were used to measure the ocular axial length in 168 high myopic eyes with cataract of 103 cases. B-scan ultrasonography was used to examine posterior scleral staphyloma. Refractive results were recorded during the follow-up after operation to evaluate the accuracy of measurement.<br />Results: The rate of posterior scleral staphyloma was 76.19%. The average postoperative error of refractive of all eyes was between -1.0 D and +1.0 D.<br />Conclusion: Accurate data of axis length can be obtained by combining results of A-scan, B-scan ultrasonography and IOL-master for high myopia with cataract, especially for patients with posterior scleral staphyloma.
Details
- Language :
- Chinese
- ISSN :
- 1000-4432
- Volume :
- 21
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Yan ke xue bao = Eye science
- Publication Type :
- Academic Journal
- Accession number :
- 17162866