Back to Search Start Over

A kinetic study of biological Cr(VI) reduction in trickling filters with different filter media types.

Authors :
Dermou E
Vayenas DV
Source :
Journal of hazardous materials [J Hazard Mater] 2007 Jun 25; Vol. 145 (1-2), pp. 256-62. Date of Electronic Publication: 2006 Nov 17.
Publication Year :
2007

Abstract

Two pilot-scale trickling filters were used in order to estimate Cr(VI) reduction through biological mechanisms in biofilm reactors operated in SBR mode with recirculation using different filter media types, i.e. plastic media and calcitic gravel. The feed concentrations of Cr(VI) examined were about 5, 10, 20, 30, 50 and 100mg/l, while the concentration of the organic carbon was constant at 400mg/l, in order to avoid carbon limitations in the bulk liquid. Maximum reduction rates of 4.8 and 4.7gCr(VI)/d were observed for feed Cr(VI) concentration of about 5mgCr(VI)/l, for the filters with the plastic support material and the gravel media, respectively. The reduction rates were significantly affected by the feed Cr(VI) concentration in both bioreactors. A dual-enzyme kinetic model was used in order to describe Cr(VI) reduction by aerobically grown mixed cultures. Model predictions were found to correspond very closely to experimental quantitative observations of Cr(VI) reduction at both pilot-scale trickling filters used.

Details

Language :
English
ISSN :
0304-3894
Volume :
145
Issue :
1-2
Database :
MEDLINE
Journal :
Journal of hazardous materials
Publication Type :
Academic Journal
Accession number :
17166660