Back to Search
Start Over
Targeting difficult accessible breast lesions: MRI-guided needle localization using a freehand technique in a 3.0 T closed bore magnet.
- Source :
-
European journal of radiology [Eur J Radiol] 2007 May; Vol. 62 (2), pp. 283-8. Date of Electronic Publication: 2007 Jan 10. - Publication Year :
- 2007
-
Abstract
- Purpose: To report the accuracy of magnetic resonance imaging (MRI)-guided needle localization for diagnosis of MRI detected suspicious breast lesions located in difficult accessible regions of the breast, using the freehand method in a 3.0 T closed bore magnet.<br />Materials and Methods: In five patients with five MRI-only breast lesions underwent MRI-guided needle localization for histopathologic evaluation of the lesions. All interventional procedures were performed in a 3.0 T MRI system with the patient in prone position and by using a dedicated phased array breast coil. MRI-guided needle localizations were performed by using a freehand technique. In our study, the high-resolution scan allowed preprocedural localization of all lesions without use of contrast enhancement. In all cases contrast-enhanced MRI was performed after insertion of the wire to confirm the tip of the wire in direct contact with the enhancing lesion.<br />Results: Needle localizations were performed in five patients. Histopathologic evaluation of tissue after surgery excision biopsy revealed one lymph node, three invasive ductal carcinoma and one ductal carcinoma in situ. Lesion size varied from 6 to 30 mm. Mean duration time was 25 min. No complications occurred during the intervention method. In the patient with the benign lesion control MRI of the breast after 6 months confirmed lesion removal.<br />Conclusions: MRI-guided needle localization by using a freehand technique in a 3.0 T closed bore magnet is a safe and accurate method for diagnosis of difficult accessible breast lesions only visible on MRI.
- Subjects :
- Breast Neoplasms surgery
Carcinoma, Ductal, Breast surgery
Carcinoma, Intraductal, Noninfiltrating surgery
Contrast Media
Equipment Design
Feasibility Studies
Female
Follow-Up Studies
Humans
Image Enhancement
Image Interpretation, Computer-Assisted
Lymphatic Metastasis
Mastectomy, Segmental
Middle Aged
Treatment Outcome
Biopsy, Needle methods
Breast Neoplasms pathology
Carcinoma, Ductal, Breast pathology
Carcinoma, Intraductal, Noninfiltrating pathology
Magnetic Resonance Imaging instrumentation
Magnetic Resonance Imaging methods
Magnetics
Subjects
Details
- Language :
- English
- ISSN :
- 0720-048X
- Volume :
- 62
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- European journal of radiology
- Publication Type :
- Academic Journal
- Accession number :
- 17218074
- Full Text :
- https://doi.org/10.1016/j.ejrad.2006.12.006