Back to Search Start Over

Use of positron emission tomography for response assessment of lymphoma: consensus of the Imaging Subcommittee of International Harmonization Project in Lymphoma.

Authors :
Juweid ME
Stroobants S
Hoekstra OS
Mottaghy FM
Dietlein M
Guermazi A
Wiseman GA
Kostakoglu L
Scheidhauer K
Buck A
Naumann R
Spaepen K
Hicks RJ
Weber WA
Reske SN
Schwaiger M
Schwartz LH
Zijlstra JM
Siegel BA
Cheson BD
Source :
Journal of clinical oncology : official journal of the American Society of Clinical Oncology [J Clin Oncol] 2007 Feb 10; Vol. 25 (5), pp. 571-8. Date of Electronic Publication: 2007 Jan 22.
Publication Year :
2007

Abstract

Purpose: To develop guidelines for performing and interpreting positron emission tomography (PET) imaging for treatment assessment in patients with lymphoma both in clinical practice and in clinical trials.<br />Methods: An International Harmonization Project (IHP) was convened to discuss standardization of clinical trial parameters in lymphoma. An imaging subcommittee developed consensus recommendations based on published PET literature and the collective expertise of its members in the use of PET in lymphoma. Only recommendations subsequently endorsed by all IHP subcommittees were adopted.<br />Recommendations: PET after completion of therapy should be performed at least 3 weeks, and preferably at 6 to 8 weeks, after chemotherapy or chemoimmunotherapy, and 8 to 12 weeks after radiation or chemoradiotherapy. Visual assessment alone is adequate for interpreting PET findings as positive or negative when assessing response after completion of therapy. Mediastinal blood pool activity is recommended as the reference background activity to define PET positivity for a residual mass > or = 2 cm in greatest transverse diameter, regardless of its location. A smaller residual mass or a normal sized lymph node (ie, < or = 1 x 1 cm in diameter) should be considered positive if its activity is above that of the surrounding background. Specific criteria for defining PET positivity in the liver, spleen, lung, and bone marrow are also proposed. Use of attenuation-corrected PET is strongly encouraged. Use of PET for treatment monitoring during a course of therapy should only be done in a clinical trial or as part of a prospective registry.

Details

Language :
English
ISSN :
1527-7755
Volume :
25
Issue :
5
Database :
MEDLINE
Journal :
Journal of clinical oncology : official journal of the American Society of Clinical Oncology
Publication Type :
Academic Journal
Accession number :
17242397
Full Text :
https://doi.org/10.1200/JCO.2006.08.2305