Back to Search Start Over

Development and comparison of four sleep spindle detection methods.

Authors :
Huupponen E
Gómez-Herrero G
Saastamoinen A
Värri A
Hasan J
Himanen SL
Source :
Artificial intelligence in medicine [Artif Intell Med] 2007 Jul; Vol. 40 (3), pp. 157-70. Date of Electronic Publication: 2007 Jun 06.
Publication Year :
2007

Abstract

Objective: The objective of the present work was to develop and compare methods for automatic detection of bilateral sleep spindles.<br />Methods and Materials: All-night sleep electroencephalographic (EEG) recordings of 12 healthy subjects with a median age of 40 years were studied. The data contained 6043 visually scored bilateral spindles occurring in frontopolar or central brain location. In the present work a new sigma index for spindle detection was developed, based on the fast Fourier transform (FFT) spectrum, aiming at approximating our previous fuzzy spindle detector. The sigma index was complemented with spindle amplitude analysis, based on finite impulse response (FIR) filtering, to form of a combination detector of bilateral spindles. In this combination detector, the spindle amplitude distribution of each recording was estimated and used to tune two different amplitude thresholds. This combination detector was compared to bilaterally extracted sigma indexes and fuzzy detections, which aim to be independent of absolute spindle amplitudes. As a fourth method a fixed spindle amplitude detector was included.<br />Results: The combination detector provided the best overall performance; in S2 sleep a 70% true positive rate was reached with a specificity of 98.6%, and a false-positive rate of 32%. The bilateral sigma indexes provided the second best results, followed by fuzzy detector, while the fixed amplitude detector provided the poorest results so that in S2 sleep a 70% true positive rate was reached with a specificity of 97.7% and false-positive rate of 46%. The spindle amplitude distributions automatically determined for each recording by the combination detector were compared to amplitudes of visually scored spindles and they proved to correspond well. Inter-hemispheric amplitude variation of visually scored bilateral spindles is also presented.<br />Conclusion: Flexibility is beneficial in the detection of bilateral spindles. The present work advances automated spindle detection and increases the knowledge of bilateral sleep spindle characteristics.

Details

Language :
English
ISSN :
0933-3657
Volume :
40
Issue :
3
Database :
MEDLINE
Journal :
Artificial intelligence in medicine
Publication Type :
Academic Journal
Accession number :
17555950
Full Text :
https://doi.org/10.1016/j.artmed.2007.04.003