Back to Search Start Over

Effect of a nurse-implemented sedation protocol on the incidence of ventilator-associated pneumonia.

Authors :
Quenot JP
Ladoire S
Devoucoux F
Doise JM
Cailliod R
Cunin N
Aubé H
Blettery B
Charles PE
Source :
Critical care medicine [Crit Care Med] 2007 Sep; Vol. 35 (9), pp. 2031-6.
Publication Year :
2007

Abstract

Objective: To determine whether the use of a nurse-implemented sedation protocol could reduce the incidence of ventilator-associated pneumonia in critically ill patients.<br />Design: Two-phase (before-after), prospective, controlled study.<br />Setting: University-affiliated, 11-bed medical intensive care unit.<br />Patients: Patients requiring mechanical ventilation for >or=48 hrs and sedative infusion with midazolam or propofol alone.<br />Interventions: During the control phase, sedatives were adjusted according to the physician's decision. During the protocol phase, sedatives were adjusted according to a protocol developed by a multidisciplinary team including nurses and physicians. The protocol was based on the Cambridge scale, and sedation level was adjusted every 3 hrs by the nurses. Standard practices, including weaning from the ventilator and diagnosis of VAP, were the same during both study phases.<br />Measurements and Main Results: A total of 423 patients were enrolled (control group, n = 226; protocol group, n = 197). The incidence of VAP was significantly lower in the protocol group compared with the control group (6% and 15%, respectively, p = .005). By univariate analysis (log-rank test), only use of a nurse-implemented protocol was significantly associated with a decrease of incidence of VAP (p < .01). A nurse-implemented protocol was found to be independently associated with a lower incidence of VAP after adjustment on Simplified Acute Physiology Score II in the multivariate Cox proportional hazards model (hazard rate, 0.81; 95% confidence interval, 0.62-0.95; p = .03). The median duration of mechanical ventilation was significantly shorter in the protocol group (4.2 days; interquartile range, 2.1-9.5) compared with the control group (8 days; interquartile range, 2.2-22.0; p = .001), representing a 52% relative reduction. Extubation failure was more frequently observed in the control group compared with the protocol group (13% and 6%, respectively, p = .01). There was no significant difference in in-hospital mortality (38% vs. 45% in the protocol vs. control group, respectively, p = .22).<br />Conclusions: In patients receiving mechanical ventilation and requiring sedative infusions with midazolam or propofol, the use of a nurse-implemented sedation protocol decreases the rate of VAP and the duration of mechanical ventilation.

Details

Language :
English
ISSN :
0090-3493
Volume :
35
Issue :
9
Database :
MEDLINE
Journal :
Critical care medicine
Publication Type :
Academic Journal
Accession number :
17855817
Full Text :
https://doi.org/10.1097/01.ccm.0000282733.83089.4d