Back to Search Start Over

The tissue distribution of fluoride in a fatal case of self-poisoning.

Authors :
Martínez MA
Ballesteros S
Piga FJ
Sánchez de la Torre C
Cubero CA
Source :
Journal of analytical toxicology [J Anal Toxicol] 2007 Oct; Vol. 31 (8), pp. 526-33.
Publication Year :
2007

Abstract

The purpose of this paper is to report a case of fluoride poisoning along with a discussion of poisoning characteristics, analytical procedures, and a review of previous reports of fatal intoxications with analytical data. A case of suicidal ingestion of 40 mL of a rust removal agent containing hydrofluoric acid and ammonium fluoride by a 33-year-old white male is presented. He had an organic personality disorder with residual schizophrenia and previous suicide attempts with therapeutic drugs and cleaning products. At admission, he presented with a Glasgow coma score of 3, third degree atrioventricular block, and asystole. Resuscitation efforts were performed during which the patient suffered two episodes of ventricular fibrillation followed by asystole. In spite of advanced resuscitation efforts and the administration of calcium chloride, he died 2.5 h after the ingestion. Analytical data in the hospital showed calcium levels of 3.1 mg/dL and metabolic acidosis. Internal findings were erosive gastritis, brain edema, and pulmonary and hepatic congestion. Quantitation of fluoride was performed using an ion-selective electrode for the anion. Disposition of fluoride in the different tissues was as follows: peripheral blood, 19.4 mg/L; urine, 670 mg/L; vitreous humor, 2.5 mg/L; liver, 40.0 mg/kg; kidney, 60.0 mg/kg; lung, 17.5 mg/kg; brain, 2.5 mg/kg; spleen, 30.0 mg/kg; bone, 0.5 mg/ kg; and gastric content, 1120 mg/L (67 mg total). Validation of the analytical method was performed using different spiked tissues, in a range of concentrations from 2.4 to 475 mg/L or mg/kg, and submitting them to dilution (1:25) to avoid the matrix effect and to bring these concentrations to the range of the aqueous calibration curve (0.19-19 mg/L). Limits of detection and quantitation were 0.02 and 0.1 mg/L, respectively. The linearity of the method, for all studies tissues, was excellent, with r(2) values of 0.999. Accuracy and precision were within 10.5% and 5.7%, respectively. Fluoride analyses using the ion selective electrode are simple, sensitive, and rapid. This report provides an extensive tissue distribution study of fluoride after a well documented case of acute poisoning. Based on the autopsy findings, patient history, toxicology results, and previously reported data the forensic pathologists ruled that the cause of death was due to a fluoride poisoning, and the manner of death was listed as suicide.

Details

Language :
English
ISSN :
0146-4760
Volume :
31
Issue :
8
Database :
MEDLINE
Journal :
Journal of analytical toxicology
Publication Type :
Academic Journal
Accession number :
17988468
Full Text :
https://doi.org/10.1093/jat/31.8.526