Prediction of enophthalmos by computer-based volume measurement of orbital fractures in a Korean population.

Authors :
Ahn HB
Ryu WY
Yoo KW
Park WC
Rho SH
Lee JH
Choi SS
Source :
Ophthalmic plastic and reconstructive surgery [Ophthalmic Plast Reconstr Surg] 2008 Jan-Feb; Vol. 24 (1), pp. 36-9.
Publication Year :
2008

Abstract

Purpose: To estimate posttraumatic enophthalmos using computer-based volume measurement of the orbital fracture to provide information on surgical guidelines.<br />Methods: The fracture volume of orbital wall fractures in 35 patients who did not undergo surgery was measured using a Rapidia work station system. Hertel ophthalmometry, diplopia, and ocular motility were investigated. The fracture volume measurements relative to the intact contralateral orbit were correlated with enophthalmos, diplopia, and ocular motility. Patients were examined at the initial visit, then at 1 week, 1 month, and 3 months.<br />Results: There was a correlation between the fracture volume and enophthalmos. Late enophthalmos increased in size in proportion to the volume of the fractured site. The predicted orbital fracture volume with an enophthalmos measurement of 2 mm or more was 2.30 ml.<br />Conclusions: Computer-based measurements of orbital fracture volume can be used to predict overall enophthalmos and provide useful information to surgeons.