Ambient aerodynamic ionization source for remote analyte sampling and mass spectrometric analysis.
- Source :
-
Analytical chemistry [Anal Chem] 2008 Jul 01; Vol. 80 (13), pp. 5266-71. Date of Electronic Publication: 2008 Jun 05. - Publication Year :
- 2008
-
Abstract
- The use of aerodynamic devices in ambient ionization source development has become increasingly prevalent in the field of mass spectrometry. In this study, an air ejector has been constructed from inexpensive, commercially available components to incorporate an electrospray ionization emitter within the exhaust jet of the device. This novel aerodynamic device, herein termed remote analyte sampling, transport, and ionization relay (RASTIR) was used to remotely sample neutral species in the ambient and entrain them into an electrospray plume where they were subsequently ionized and detected using a linear ion trap Fourier transform mass spectrometer. Two sets of experiments were performed in the ambient environment to demonstrate the device's utility. The first involved the remote (approximately 1 ft) vacuum collection of pure sample particulates (i.e., dry powder) from a glass slide, entrainment and ionization at the ESI emitter, and mass spectrometric detection. The second experiment involved the capture (vacuum collection) of matrix-assisted laser desorbed proteins followed by entrainment in the ESI emitter plume, multiple charging, and mass spectrometric detection. This approach is in principle a RASTIR-assisted matrix-assisted laser desorption electrospray ionization source (Sampson, J. S.; Hawkridge, A. M.; Muddiman, D. C. J. Am. Soc. Mass Spectrom. 2006, 17, 1712-1716; Rapid Commun. Mass Spectrom. 2007, 21, 1150-1154.). A detailed description of the device construction, operational parameters, and preliminary small molecule and protein data are presented.
- Subjects :
- Acetaminophen antagonists & inhibitors
Acetaminophen chemistry
Caffeine analysis
Caffeine chemistry
Natriuretic Peptide, Brain analysis
Natriuretic Peptide, Brain chemistry
Spectrometry, Mass, Electrospray Ionization instrumentation
Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization instrumentation
Ubiquitin analysis
Ubiquitin chemistry
Spectrometry, Mass, Electrospray Ionization methods
Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization methods
Subjects
Details
- Language :
- English
- ISSN :
- 1520-6882
- Volume :
- 80
- Issue :
- 13
- Database :
- MEDLINE
- Journal :
- Analytical chemistry
- Publication Type :
- Academic Journal
- Accession number :
- 18529018
- Full Text :