Off-resonance angiography: a new method to depict vessels--phantom and rabbit studies.

Authors :
Korosoglou G
Shah S
Vonken EJ
Gilson WD
Schär M
Tang L
Kraitchman DL
Boston RC
Sosnovik DE
Weiss RG
Weissleder R
Stuber M
Source :
Radiology [Radiology] 2008 Nov; Vol. 249 (2), pp. 501-9. Date of Electronic Publication: 2008 Sep 09.
Publication Year :
2008

Abstract

Purpose: To evaluate the utility of inversion recovery with on-resonant water suppression (IRON) in combination with injection of the long-circulating monocrystalline iron oxide nanoparticle (MION)-47 for contrast material-enhanced magnetic resonance (MR) angiography.<br />Materials and Methods: Experiments were approved by the institutional animal care committee. Eleven rabbits were imaged at baseline before injection of a contrast agent and then serially 5-30 minutes, 2 hours, 1 day, and 3 days after a single intravenous bolus injection of 80 micromol of MION-47 per kilogram of body weight (n = 6) or 250 micromol/kg MION-47 (n = 5). Conventional T1-weighted MR angiography and IRON MR angiography were performed on a clinical 3.0-T imager. Signal-to-noise and contrast-to-noise ratios were measured in the aorta of rabbits in vivo. Venous blood was obtained from the rabbits before and after MION-47 injection for use in phantom studies.<br />Results: In vitro blood that contained MION-47 appeared signal attenuated on T1-weighted angiograms, while characteristic signal-enhanced dipolar fields were observed on IRON angiograms. In vivo, the vessel lumen was signal attenuated on T1-weighted MR angiograms after MION-47 injection, while IRON supported high intravascular contrast by simultaneously providing positive signal within the vessels and suppressing background tissue (mean contrast-to-noise ratio, 61.9 +/- 12.4 [standard deviation] after injection vs 1.1 +/- 0.4 at baseline, P < .001). Contrast-to-noise ratio was higher on IRON MR angiograms than on conventional T1-weighted MR angiograms (9.0 +/- 2.5, P < .001 vs IRON MR angiography) and persisted up to 24 hours after MION-47 injection (76.2 +/- 15.9, P < .001 vs baseline).<br />Conclusion: IRON MR angiography in conjunction with superparamagnetic nanoparticle administration provides high intravascular contrast over a long time and without the need for image subtraction.<br /> ((c) RSNA, 2008.)

Details

Language :
English
ISSN :
1527-1315
Volume :
249
Issue :
2
Database :
MEDLINE
Journal :
Radiology
Publication Type :
Academic Journal
Accession number :
18780823
Full Text :
https://doi.org/10.1148/radiol.2491071706