Back to Search
Start Over
Variability of interpretive accuracy among diagnostic mammography facilities.
- Source :
-
Journal of the National Cancer Institute [J Natl Cancer Inst] 2009 Jun 03; Vol. 101 (11), pp. 814-27. Date of Electronic Publication: 2009 May 26. - Publication Year :
- 2009
-
Abstract
- Background: Interpretive performance of screening mammography varies substantially by facility, but performance of diagnostic interpretation has not been studied.<br />Methods: Facilities performing diagnostic mammography within three registries of the Breast Cancer Surveillance Consortium were surveyed about their structure, organization, and interpretive processes. Performance measurements (false-positive rate, sensitivity, and likelihood of cancer among women referred for biopsy [positive predictive value of biopsy recommendation {PPV2}]) from January 1, 1998, through December 31, 2005, were prospectively measured. Logistic regression and receiver operating characteristic (ROC) curve analyses, adjusted for patient and radiologist characteristics, were used to assess the association between facility characteristics and interpretive performance. All statistical tests were two-sided.<br />Results: Forty-five of the 53 facilities completed a facility survey (85% response rate), and 32 of the 45 facilities performed diagnostic mammography. The analyses included 28 100 diagnostic mammograms performed as an evaluation of a breast problem, and data were available for 118 radiologists who interpreted diagnostic mammograms at the facilities. Performance measurements demonstrated statistically significant interpretive variability among facilities (sensitivity, P = .006; false-positive rate, P < .001; and PPV2, P < .001) in unadjusted analyses. However, after adjustment for patient and radiologist characteristics, only false-positive rate variation remained statistically significant and facility traits associated with performance measures changed (false-positive rate = 6.5%, 95% confidence interval [CI] = 5.5% to 7.4%; sensitivity = 73.5%, 95% CI = 67.1% to 79.9%; and PPV2 = 33.8%, 95% CI = 29.1% to 38.5%). Facilities reporting that concern about malpractice had moderately or greatly increased diagnostic examination recommendations at the facility had a higher false-positive rate (odds ratio [OR] = 1.48, 95% CI = 1.09 to 2.01) and a non-statistically significantly higher sensitivity (OR = 1.74, 95% CI = 0.94 to 3.23). Facilities offering specialized interventional services had a non-statistically significantly higher false-positive rate (OR = 1.97, 95% CI = 0.94 to 4.1). No characteristics were associated with overall accuracy by ROC curve analyses.<br />Conclusions: Variation in diagnostic mammography interpretation exists across facilities. Failure to adjust for patient characteristics when comparing facility performance could lead to erroneous conclusions. Malpractice concerns are associated with interpretive performance.
- Subjects :
- Adult
Aged
Area Under Curve
Biopsy
Breast Neoplasms pathology
Cancer Care Facilities organization & administration
Confounding Factors, Epidemiologic
Defensive Medicine
Diagnosis, Differential
Early Detection of Cancer
False Positive Reactions
Female
Humans
Liability, Legal
Malpractice
Mammography standards
Mass Screening methods
Middle Aged
Multivariate Analysis
Odds Ratio
Predictive Value of Tests
ROC Curve
Radiographic Image Interpretation, Computer-Assisted
Sensitivity and Specificity
United States
Breast Neoplasms diagnostic imaging
Cancer Care Facilities statistics & numerical data
Clinical Competence standards
Mammography statistics & numerical data
Observer Variation
Subjects
Details
- Language :
- English
- ISSN :
- 1460-2105
- Volume :
- 101
- Issue :
- 11
- Database :
- MEDLINE
- Journal :
- Journal of the National Cancer Institute
- Publication Type :
- Academic Journal
- Accession number :
- 19470953
- Full Text :
- https://doi.org/10.1093/jnci/djp105