Back to Search
Start Over
Dose reduction in spiral CT coronary angiography with dual-source equipment. Part I. A phantom study applying different prospective tube current modulation algorithms.
- Source :
-
La Radiologia medica [Radiol Med] 2009 Oct; Vol. 114 (7), pp. 1037-52. Date of Electronic Publication: 2009 Aug 07. - Publication Year :
- 2009
-
Abstract
- Purpose: The authors sought to compare different algorithms for dose reduction in retrospectively echocardiographically (ECG)-gated dual-source computed tomography (CT) coronary angiography (DSCT-CA) in a phantom model.<br />Materials and Methods: Weighted CT dose index (CTDI) was measured by using an anthropomorphic phantom in spiral cardiac mode (retrospective ECG gating) at five pitch values adapted with two heart-rate-adaptive ECG pulsing windows using four algorithms: narrow pulsing window, with tube current reduction to 20% (A) and 4% (B) of peak current outside the pulsing window; wide pulsing window, with tube current reduction to 20% (C) and 4% (D). Each algorithm was applied at different heart rates (45, 60, 75, 90, 120 bpm).<br />Results: Mean CTDI volume (CTDIvol) was 36.9+/-9.7 mGy, 23.9+/-5.6 mGy, 49.7+/-16.2 mGy and 38.5+/-12.3 mGy for A, B, C and D, respectively. Consistent dose reduction was observed with protocols applying the 4% tube current reduction (B and D). Using the conversion coefficient for the chest, the mean effective dose was the highest for C (9.6 mSv) and the lowest for B (4.6 mSv). Heart-ratedependent pitch values (pitch=0.2, 0.26, 0.34, 0.43, 0.5) and the use of heart-rate-adaptive ECG pulsing windows provided a significant decrease in the CTDIvol with progressively higher heart rates (45, 60, 75, 90, 120 bpm), despite using wider pulsing windows.<br />Conclusions: Radiation exposure with DSCT-CA using a narrow pulsing window significantly decreases when compared with a wider pulsing window. When using a protocol with reduced tube current to 4%, the radiation dose is significantly lower.
- Subjects :
- Absorptiometry, Photon
Algorithms
Coronary Angiography methods
Equipment Design
Heart diagnostic imaging
Humans
Models, Theoretical
Reproducibility of Results
Sensitivity and Specificity
Thermoluminescent Dosimetry
Coronary Angiography instrumentation
Electrocardiography
Heart Rate
Phantoms, Imaging
Radiation Dosage
Tomography, Spiral Computed
Subjects
Details
- Language :
- English
- ISSN :
- 1826-6983
- Volume :
- 114
- Issue :
- 7
- Database :
- MEDLINE
- Journal :
- La Radiologia medica
- Publication Type :
- Academic Journal
- Accession number :
- 19662339
- Full Text :
- https://doi.org/10.1007/s11547-009-0437-z