Back to Search
Start Over
Bifocal pacing in the right ventricle: an alternative to resynchronization when left ventricular access is not possible in end-stage heart failure patients.
- Source :
-
Cardiology journal [Cardiol J] 2010; Vol. 17 (1), pp. 35-41. - Publication Year :
- 2010
-
Abstract
- Background: It has been reported that bifocal pacing (BiF) in the right ventricle might be an alternative to unsuccessful left ventricular lead implantation. This case report presents an assessment of the clinical and hemodynamic parameters during a three month follow-up in patients implanted with right ventricular BiF.<br />Methods: Eight patients who underwent unsuccessful left ventricular lead implantation were implanted with a bifocal system in the right ventricular. Leads were implanted in the right atrium appendage, the apex and the right ventricular outflow tract and connected to the cardiac resynchronization therapy pacemaker. All patients performed a sixminute walking test and underwent echocardiography after the implantation and after the three month follow-up.<br />Results: We found a significant performance increase in the six minute walking test and reduction in New York Heart Association class and mitral regurgitation in echocardiography study, as well as a significant increase in left ventricular ejection fraction, and cardiac output directly after the implantation, as well as at threemonth follow-up in patients after BiF implantation.<br />Conclusions: Right ventricular bifocal pacing in patients with cardiac resynchronization therapy indication and unsuccessful left ventricular lead placement seems to be a beneficial treatment for heart failure. Satisfactory hemodynamic and clinical results were observed directly after BiF implantation and during the three month follow-up.
- Subjects :
- Aged
Cardiac Output
Echocardiography
Electrocardiography
Exercise Test
Female
Follow-Up Studies
Heart Failure diagnosis
Humans
Male
Middle Aged
Mitral Valve Insufficiency diagnostic imaging
Mitral Valve Insufficiency physiopathology
Pacemaker, Artificial
Prosthesis Implantation methods
Reoperation
Stroke Volume
Treatment Failure
Treatment Outcome
Walking
Cardiac Pacing, Artificial methods
Heart Failure physiopathology
Heart Failure therapy
Heart Ventricles physiopathology
Subjects
Details
- Language :
- English
- ISSN :
- 1898-018X
- Volume :
- 17
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Cardiology journal
- Publication Type :
- Academic Journal
- Accession number :
- 20104455