Back to Search Start Over

High-throughput tissue homogenization method and tissue-based quality control materials for a clinical assay of the intestinal disaccharidases.

Authors :
Lu J
Grenache DG
Source :
Clinica chimica acta; international journal of clinical chemistry [Clin Chim Acta] 2010 May 02; Vol. 411 (9-10), pp. 754-7. Date of Electronic Publication: 2010 Feb 11.
Publication Year :
2010

Abstract

Background: The definitive biochemical test for the diagnosis of disaccharidase deficiencies is the determination of enzyme activities in small bowel mucosa. Traditional methods of tissue homogenization are limited by low throughput. Lack of tissue-based quality control materials is a limitation for clinical laboratories that perform tests of the intestinal disaccharidases. The objectives of this study were to develop a method for determining disaccharidase activities using a high-throughput homogenization method and to create matrix-appropriate quality control materials.<br />Methods: Intestinal mucosa was homogenized using three different methods. Activities of lactase, maltase, palatinase, and sucrase were determined by measuring glucose liberated from a hydrolysis reaction with disaccharide substrates and normalized to total protein concentration. Tissue-based quality control materials were developed from pig intestine and pooled clinical specimens.<br />Results: A high-throughput homogenization method processed 24 specimens in 2 min compared to 1 specimen per 2 min for traditional methods. There were no significant differences (p>0.90) in enzyme activities as a function of the homogenization method used. 92 determinations of enzyme activities from 23 clinical specimens showed acceptable agreement (y=1.13x-6.6) and were highly correlated (r=0.95) as compared to results obtained by an external laboratory. Enzyme activities were variably inactivated by temperatures > or = 60 degrees C. Pig intestinal mucosa produced non-deficient enzyme activities while deficient activities were produced by combining equal volumes of unheated and heat-inactivated homogenates pooled from clinical specimens.<br />Conclusions: A high-throughput method of tissue homogenization was more efficient than traditional methods and did not affect enzyme activities. Matrix-appropriate quality control materials can be created from pig intestine and pooled human homogenates.<br /> (Copyright 2010 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-3492
Volume :
411
Issue :
9-10
Database :
MEDLINE
Journal :
Clinica chimica acta; international journal of clinical chemistry
Publication Type :
Academic Journal
Accession number :
20153307
Full Text :
https://doi.org/10.1016/j.cca.2010.02.009