Back to Search
Start Over
Deviations in delineated GTV caused by artefacts in 4DCT.
- Source :
-
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology [Radiother Oncol] 2010 Jul; Vol. 96 (1), pp. 61-6. Date of Electronic Publication: 2010 Jun 01. - Publication Year :
- 2010
-
Abstract
- Background and Purpose: Four-dimensional computed tomography (4DCT) is used for breathing-adapted radiotherapy planning. Irregular breathing, large tumour motion or interpolation of images can cause artefacts in the 4DCT. This study evaluates the impact of artefacts on gross tumour volume (GTV) size.<br />Material and Methods: In 19 4DCT scans of patients with peripheral lung tumours, GTV was delineated in all bins. Variations in GTV size between bins in each 4DCT scan were analysed and correlated to tumour motion and variations in breathing signal amplitude and breathing signal period. End-expiration GTV size (GTVexp) was considered as reference for GTV size. Intra-session delineation error was estimated by re-delineation of GTV in eight of the 4DCT scans.<br />Results: In 16 of the 4DCT scans the maximum deviations from GTVexp were larger than could be explained by delineation error. The deviations were largest in the bins adjacent to the end-inspiration bin. The coefficient of variation of GTV size was significantly correlated to tumour motion in the cranio-caudal direction, but no significant correlation was found to breathing signal variations.<br />Conclusion: We found considerable variations in GTV size throughout the 4DCT scans. Awareness of the error introduced by artefacts is important especially if radiotherapy planning is based on a single 4DCT bin.<br /> (Copyright 2010 Elsevier Ireland Ltd. All rights reserved.)
- Subjects :
- Carcinoma, Non-Small-Cell Lung pathology
Carcinoma, Non-Small-Cell Lung radiotherapy
Dose Fractionation, Radiation
Female
Humans
Lung Neoplasms pathology
Lung Neoplasms radiotherapy
Motion
Respiration
Risk Factors
Sampling Studies
Tumor Burden
Artifacts
Carcinoma, Non-Small-Cell Lung diagnostic imaging
Four-Dimensional Computed Tomography methods
Lung Neoplasms diagnostic imaging
Radiotherapy Planning, Computer-Assisted
Subjects
Details
- Language :
- English
- ISSN :
- 1879-0887
- Volume :
- 96
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
- Publication Type :
- Academic Journal
- Accession number :
- 20570002
- Full Text :
- https://doi.org/10.1016/j.radonc.2010.04.019